Issuing stocks in advanced manufacturing caused errors reporting negative stock always.
[fa-stable.git] / manufacturing / work_order_issue.php
index 236d4ab5c2f02feb2c04ebdae8a330688d8a7a8c..7054f94a2f86cd2e12de80a1f3f96ff47968dd17 100644 (file)
@@ -62,8 +62,6 @@ function handle_new_order()
                unset ($_SESSION['issue_items']);
        }
 
-     Session_register("issue_items");
-
      $_SESSION['issue_items'] = new items_cart(ST_MANUISSUE);
      $_SESSION['issue_items']->order_id = $_GET['trans_no'];
 }
@@ -101,10 +99,9 @@ function can_process()
        }
 
        $failed_item = $_SESSION['issue_items']->check_qoh($_POST['Location'], $_POST['date_'], !$_POST['IssueType']);
-       if ($failed_item != -1
+       if ($failed_item) 
        {
-       display_error( _("The issue cannot be processed because an entered item would cause a negative inventory balance :") .
-               " " . $failed_item->stock_id . " - " .  $failed_item->item_description);
+               display_error(_("The issue cannot be processed because it would cause negative inventory balance for marked items as of document date or later."));
                return false;
        }
 
@@ -136,7 +133,7 @@ if (isset($_POST['Process']) && can_process())
 
 function check_item_data()
 {
-       if (!check_num('qty', 0))
+       if (input_num('qty') == 0 || !check_num('qty', 0))
        {
                display_error(_("The quantity entered is negative or invalid."));
                set_focus('qty');
@@ -214,7 +211,7 @@ echo "<br>";
 
 start_form();
 
-start_table(TABLESTYLE, "width=90%", 10);
+start_table(TABLESTYLE, "width='90%'", 10);
 echo "<tr><td>";
 display_issue_items(_("Items to Issue"), $_SESSION['issue_items']);
 issue_options_controls();